CE Certification Disposable Stone Retrieval Baskets Manufacturers, Suppliers

• Material: 304 or 316 stainless steel • Sharpness test: ≤ 0.5N penetration force • Sheath Material: PTFE with stainless steel coil reinforcement (optional) • Sheath Kink resistance: Pass 180° bend test • Handle Material: ABS medical grade • EO sterile

Product Description

Precise submucosal lifting for EMR, ESD, and sclerotherapy – one needle, one procedure, one patient.
Zero infection, zero dulling, zero reprocessing – just sharp, safe performance every time.
✦
Always sharp – Fresh stainless steel needle every single use
🛡
Zero infection risk – Sterile, single-use, no reprocessing
⚙
Scope-safe – Retractable needle protects the working channel
🎯
Dial-in depth – Adjustable extension from 4mm to 10mm
🔒
No leaks – Secure Luer lock connection
👁
See it clearly – Highly visible tip under endoscopy
⚡
Slides easy – Low-friction PTFE sheath
Model Diameter D±0.1 (mm) Working Length L±50 (mm) Needle Size (diameter/length) Working Channel
ZRH-PN-1812-254 Φ1.8 1200 25 G, 4mm ≥2.0
ZRH-PN-2418-214 Φ2.4 1800 21 G, 4mm ≥2.8
★ ZRH-PN-2418-234 Φ2.4 1800 23 G, 4mm ≥2.8
ZRH-PN-2418-254 Φ2.4 1800 25 G, 4mm ≥2.8
ZRH-PN-2418-216 Φ2.4 1800 21 G, 6mm ≥2.8
ZRH-PN-2418-236 Φ2.4 1800 23 G, 6mm ≥2.8
ZRH-PN-2418-256 Φ2.4 1800 25 G, 6mm ≥2.8
ZRH-PN-2423-214 Φ2.4 2300 21 G, 4mm ≥2.8
ZRH-PN-2423-234 Φ2.4 2300 23 G, 4mm ≥2.8
ZRH-PN-2423-254 Φ2.4 2300 25 G, 4mm ≥2.8
ZRH-PN-2423-216 Φ2.4 2300 21 G, 6mm ≥2.8
★ ZRH-PN-2423-236 Φ2.4 2300 23 G, 6mm ≥2.8
ZRH-PN-2423-256 Φ2.4 2300 25 G, 6mm ≥2.8
★ Commonly selected models
✅ Core Uses
  • EMR/ESD lifting: Inject fluid to raise the lesion before resection. (Lift – Inject fluid beneath a polyp to raise it before cutting.)
  • Sclerotherapy: Deliver sclerosant into varices or hemorrhoids. (Inject – Deliver sclerosant directly into varices or hemorrhoids.)
  • Contrast injection: Inject dye for fluoroscopic guidance. (Dye – Push contrast through the needle for fluoroscopic imaging.)
  • Drug delivery: Administer local therapeutic agents. (Treat – Infuse medication exactly where the lesion lives.)
  • Tattooing: Mark lesions for future surgical localization. (Mark – Place a tattoo next to a lesion for surgical navigation.)
🔬 Technical Specifications
  • Material: 304 or 316 stainless steel
  • Sharpness test: ≤ 0.5N penetration force
  • Sheath Material: PTFE with stainless steel coil reinforcement (optional)
  • Sheath Kink resistance: Pass 180° bend test
  • Handle Material: ABS medical grade
  • Sterility: EO sterile
📦 From ZRH med. - Logistics & Supply Chain
Producing Lead Time: 2-3 weeks after payment received, depends on your order quantity
Delivery Methods: 1. By Express: Fedex, UPS, TNT, DHL, SF express 3-5day, 5-7days.
2. By Road: Domestic and neighbour country : 3-10 days
3. By Sea : 5-45 day all over the world.
4. By Air : 5-10 days all over the world.
Loading Ports: Shenzhen, Yantian, Shekou, Hong Kong, Xiamen, Ningbo, Shanghai, Nanjing, Qingdao (According to your requirement)
Delivery Terms & Documents: Terms: EXW, FOB, CIF, CFR, C&F, DDU, DDP, FCA, CPT
Shipping Documents: B/L, Commercial Invoice, Packing List
Q1: What are the main clinical applications of this endoscopic injection needle?
This single-use device is primarily designed for fluid injection during endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD), endoscopic sclerotherapy for esophageal and gastric varices or hemorrhoids, contrast dye delivery for fluoroscopy, tattooing for surgical localization, and targeted drug administration.
Q2: How does the design protect the endoscope channel from damage?
The device features an easy-to-operate retractable needle system and a low-friction PTFE outer sheath. The needle remains safely retracted within the protective sheath during insertion and advancement, preventing any scratching or puncturing of the flexible endoscope working channel.
Q3: Which models are most commonly recommended for standard procedures?
The most popular configurations are model ZRH-PN-2418-234 (Φ2.4mm outer diameter, 1800mm working length, 23G needle with 4mm extension) and model ZRH-PN-2423-236 (Φ2.4mm outer diameter, 2300mm working length, 23G needle with 6mm extension). Both require a working channel of ≥2.8mm.
Q4: What material grades and quality standards are applied?
The puncture needle is made of medical-grade 304 or 316 stainless steel with a tested penetration force of ≤0.5N to ensure effortless puncture. The handle is made of medical-grade ABS with a secure Luer lock, the sheath passes a 180° kink-resistance bend test, and the entire device is sterilized by Ethylene Oxide (EO).
Q5: What is the typical lead time and available international shipping terms?
The standard production lead time is typically 2 to 3 weeks following payment confirmation, depending on order size. Orders can be shipped via Express, Air, Sea, or Road under flexible Incoterms including EXW, FOB, CIF, DDP, CFR, and others, accompanied by standard documentation (B/L, Commercial Invoice, Packing List).

Related Products